Field test instruments and fusion splicers for network installers and operators.
102 products in this department
Browse the departmentLaboratory instrumentation for photonics, laser technology and R&D.
226 products in this department
Browse the departmentFiber-optic sensing systems: DAS, DTS, DSS, FBG and OFDR.
84 products in this department
Browse the departmentEye tracking, fNIRS, EEG and biometrics for science and business.
35 products in this department
Browse the departmentHome » Products » Research & Scientific Instruments » Biometrics » EMG (Muscle Activity) » fEMG Facial Electromyogram Smart Amplifier
The fEMG100D amplifier from the latest “Smart Amplifier” series has been precisely optimized for recording the most subtle facial electromyographic signals (e.g. the zygomatic muscle and the muscle that furrows the brow). Thanks to an ultra-high gain factor (Gain: x2000) and an extremely low noise floor (0.2 µV rms), the device flawlessly captures the minimal voltages of the facial muscles. The “Smart” design allows the module to be clipped directly onto the subject’s clothing, drastically shortening lead wires and eliminating motion artifacts typical of traditional systems.
The fEMG Facial Electromyogram Smart Amplifier is designed specifically for recording EMG signals from the face and the electrical activity of other small muscle groups. It enables analysis of facial expressions and startle paradigms.
EMG: Electromyography, Psychophysiology, Biomechanics, Exercise Physiology, Sleep Research, Remote Monitoring
Telemetry data is transmitted at a rate of 2000 Hz, ensuring ultra-high waveform resolution at the receiver. The system is equipped with internal, optional Highpass and Lowpass filters that compensate for possible hand-motion artifacts.
The module simulates a classic “wired” connection to the computer, while at the same time delivering the full benefits of a Wearable system:
Body mounting: The transmitter can be easily clipped onto the patient’s wrist using the included elastic Velcro strap, or worn in the dedicated BioNomadix Shirt.
Noise immunity (CMRR): Because the device is battery-powered and isolated from the mains (no 50/60 Hz power cables on the patient), the common-mode rejection ratio is extremely high. Notch Filters are typically not required at all!
Safety: The absence of physical contact between the patient’s equipment and the fixed power installation minimizes any risk of electric shock.
MP200 Research System, AMI100D Amplifier Input Module
The BIOPAC acquisition system relies on an efficient chain of interconnected modules that ensure crystal-clear signal integrity from the patient all the way to the final waveform on the screen.
Records the physiological signal directly from the patient, amplifying and hardware-filtering it to ensure an absolutely clean and stable reading.
Passes the amplified physiological signal directly to the MP160 or MP200 research station. Guarantees lossless, real-time transmission.
The main station synchronizes signals from other interfaces (e.g. an Eye-Tracker) and reliably transmits them over a cable via the Ethernet protocol to the powerful AcqKnowledge software on the researcher's computer.
Key technical parameters of the transmitter and receiver for both recorded physiological channels.
| Parameter | Value / Specification |
|---|---|
| Sampling Rate | Depends on the MP station (up to 100 kHz, typically 2000 Hz) |
| Signal Resolution | 16-bit (for MP160) / 24-bit (for MP200) |
| Range / Gain | x2000 (Optimized for facial microvoltages) |
| Hardware Filters | Hardware IIR: High Pass 10 Hz / Low Pass 500 Hz |
| Power Supply | Isolated, powered from the station via the AMI100D module |
| Noise Floor | 0.2 µV rms (in the 10–500 Hz band) |
Related products
BiometricsKinematics (Motion & Goniometry)
BiometricsDynamometry (Force & Pressure)
BiometricsKinematics (Motion & Goniometry)
Product: fEMG Facial Electromyogram Smart Amplifier