Browse the departmentHome » Products » Research & Scientific Instruments » Biometrics » PPG / SpO2 (Pulse & Saturation) » Wired PPG amplifier (BIOPAC PPG100D)
A wired photoplethysmography (PPG) amplifier from the BIOPAC Smart Amplifier series — measurement electronics placed directly at the optical transducer reduce interference and motion artifacts, and acquisition parameters configure automatically in AcqKnowledge. Requires the AMI100D interface and an MP160 or MP200 unit (not MP150), plus AcqKnowledge 5.0.4 or newer.
PPG100D is an amplifier from the Smart Amplifier series — measurement electronics placed directly at the optical transducer, rather than in a module near the acquisition unit.
Because the amplifier sits close to the transducer, the signal is less susceptible to electromagnetic interference (EMI) and motion artifacts, and acquisition parameters configure automatically in AcqKnowledge once connected.
Illustrative photo of the full Smart Amplifier 100D family — the PPG100D module shares the identical housing.
The PPG100D module itself does not record or store data on its own. It requires connection through the AMI100D interface to an MP160 or MP200 data acquisition unit (Smart Amplifier modules are NOT compatible with the MP150), together with AcqKnowledge version 5.0.4 or later.
In addition, PPG100D requires a separately ordered photoplethysmographic transducer — see the section below for details. The module connects via a 3 m RJ12 cable to the AMI100D interface, and the recorded signal is placed on the shared, synchronized timeline together with the other modules in the system.
PPG100D is the amplifier alone — a separately ordered photoplethysmographic transducer is required for measurement.
Transducer on the finger (BN-PULSE-XDCR variant).
BN-PULSE-XDCR / BN-PULSEEAR-XDCR
One family of photoplethysmographic transducers, available in two measurement-site variants — choose according to the study protocol.
The Smart Amplifier architecture places the amplifier right next to the optical transducer — significantly reducing EMI interference and motion artifacts compared with a traditional module located at the acquisition unit.
Once connected, the module automatically configures acquisition parameters in AcqKnowledge — no manual switch settings required.
AcqKnowledge automatically calculates a derived signal from the recorded PPG waveform — pulse rate — with no additional configuration required from the researcher.
Two transducer variants — BN-PULSE-XDCR (finger) and BN-PULSEEAR-XDCR (earlobe) — let you match the measurement site to the study protocol and participant preference.
Click the point on the image to see the typical placement of the PPG transducer on the fingertip (BN-PULSE-XDCR). The transducer is also available in an earlobe variant (BN-PULSEEAR-XDCR) — the choice depends on the ordered variant and the study protocol.
Placement confirmed in the source materials for PPG100D together with the corresponding BN-PULSE-XDCR and BN-PULSEEAR-XDCR transducers.
Attached to the fingertip (here: the index finger), usually with a strap. The BN-PULSEEAR-XDCR variant, an earlobe clip, is also available as an alternative.
The BN-PULSE-XDCR transducer placed on the fingertip (or BN-PULSEEAR-XDCR on the earlobe) is connected to the PPG100D module.
The module amplifies the signal right at the transducer and sends it over an RJ12 cable to the AMI100D interface, and from there to the acquisition unit.
Automatic channel configuration, recording of the PPG waveform, and calculation of the pulse rate.
PPG measurement supports research on heart rate variability and autonomic nervous system responses.
Determining pulse rate and its variability as an indicator of autonomic nervous system activity.
Recording cardiovascular responses to stress stimuli in psychophysiological protocols.
PPG signal as an indicator of autonomic responses accompanying cognitive tasks.
PPG as one of the physiological signals used in sleep-study protocols.
PPG100D places the amplifier directly at the transducer (instead of in a module near the acquisition unit), which reduces EMI interference and motion artifacts, and automatically configures parameters in AcqKnowledge. It also requires the AMI100D interface and an MP160/MP200 unit (not the MP150), unlike the older 100C series, which used a different transducer — the TSD200, rather than the BN-PULSE-XDCR.
BN-PULSE-XDCR (fingertip) and BN-PULSEEAR-XDCR (earlobe) are two variants of the same PPG transducer — the choice of measurement site depends on the study protocol and participant preference. Both connect directly to the PPG100D module.
Only the MP160 or MP200, via the AMI100D interface, with AcqKnowledge software version 5.0.4 or later. It does not work with the MP150.
Related products
BiometricsECG (Heart Activity)Research & Scientific InstrumentsRSP (Respiration)
Product: Wired PPG amplifier (BIOPAC PPG100D)