Photonics & R&D

Photonics and R&D covers the instruments, components and tools required to build, commission and test optical and fibre setups. Interlab supplies laser sources, optics and optomechanics, analyzers, interferometers, inspection microscopes, fibre tools and processing equipment. Selection begins with wavelength, power, signal type, optical geometry and the parameter to be measured, followed by mechanical compatibility, connectors, software and accessories.

Product Categories

Filters

Fiber Splicing & ProcessingPhotonics & R&D

Passive Fiber Optic ComponentsPhotonics & R&D

Passive Fiber Optic ComponentsPhotonics & R&D

Fiber Splicing & ProcessingTapering

Lab Fusion SplicersPhotonics & R&D

Equipment for photonics laboratories and R&D setups

A complete photonics setup contains a source, optical path, sample or device under test, detection system and measurement instruments. Every layer must be compatible in wavelength, aperture, power, polarisation, fibre type and mechanical geometry.

Sources and modulation

Tunable, pulsed, DFB and supercontinuum lasers together with components for beam control.

Optical path

Lenses, mirrors, filters, positioners, stages, mounts and optomechanics.

Measurement and analysis

Spectrum and signal analyzers, detectors, meters, interferometers and imaging systems.

Human behaviour and physiology projects should start under behavioural research instruments. Field network work is covered under fibre meters and fusion splicers.

Fibre tools for processing, inspection and measurement

Laboratory fibre work requires repeatable stripping, cleaving, positioning and surface protection. Specialty fibres, non-standard diameters and multicore structures may require dedicated holders and process programmes.

Fibre splicing and processing includes equipment for splicing, cleaving, tapering and preparing standard and specialty fibres. Laboratory splicer accessories include holders, electrodes and positioning parts matched to the process.

Quality control may include surface inspection, geometry measurement, propagation analysis or interferometry. Relevant equipment includes inspection microscopes and optical interferometers.

Optics and optomechanics for research setups

Optical-path stability depends on both the elements and their mounting. Optics must be selected for spectral range, aperture, coating, surface quality, focal length and power handling. Optomechanics must match element format, adjustment range, resolution, repeatability and thread standard.

Design the setup around a common optical axis and mechanical base. Define beam height, source and sample positions first, then select mounts, stages and adjustment components. This avoids combining individually correct parts that cannot form a stable system.

Fibre paths add fibre type, mode-field diameter, connector, bend radius and coupling method. High-power sources also require damage-threshold and thermal checks.

How to select photonics instruments for a project

Begin with a setup diagram and a list of parameters to generate, control or measure. Describe the complete path and boundary conditions rather than only a device name.

  • Spectral range: wavelengths of the source, optics, detector and instruments.
  • Signal level: average and peak power, dynamic range and required SNR.
  • Geometry: free-space beam or fibre, fibre type, connectors, aperture and axis height.
  • Measured parameter: spectrum, power, phase, geometry, surface, loss or time response.
  • Integration: drivers, interfaces, automation, data format and mechanical compatibility.

Attach a sketch, expected ranges, existing equipment and space constraints. This reveals missing adapters and accessories before the system is ordered.

Send the setup diagram

Identify the source, optical path, sample, measured parameter and existing equipment.

Ask about photonics equipment

Frequently asked questions - Photonics and R&D

Where should I start when specifying a photonics setup?

First define the sample, measurand, wavelength range, power levels, required uncertainty and control method. Then select the source, optical path and mechanics, sample or fibre preparation, and the appropriate analyser or measurement platform.

How does an optical spectrum analyser differ from an interferometer?

An optical spectrum analyser separates signal power by wavelength or frequency. An interferometer uses interference to measure other properties depending on its design, such as surface geometry, optical path or component parameters. The instruments answer different measurement questions.

When should I choose a measurement platform rather than a standalone instrument?

A modular platform is useful when a setup requires multiple channels, path switching, repeatable sequences and future expansion. A standalone instrument may be more suitable for one well-defined measurement. The decision depends on workflow, modules and automation requirements.

Can photonics instruments be automated?

Many instruments provide remote-control interfaces, drivers or APIs, but the functions and compatibility depend on the model and software version. Check commands, triggering, required libraries, licences and result formats for the exact configuration before selection.

Can every fibre-splicing system process specialty fibres?

No. Compatibility depends on fibre geometry, cladding diameter, fibre type, observation and alignment method, holders, heat source and available process programs. Confirm the configuration for the exact fibre and required splice quality.

What information is needed to select photonics equipment?

Prepare an optical-path diagram, sample description, spectral range, power levels, connector or port types and count, measured parameters, required accuracy and dynamic range, mechanical conditions, and control, export and expansion requirements.

How should laboratory fibre tools be selected?

Define fibre type and diameter, coating, process—cleaving, splicing, tapering or end preparation—and repeatability. Specialty fibres may require dedicated holders, process programmes and accessories.