Browse the departmentHome » Products » Research & Scientific Instruments » Biometrics » EGG (Electrogastrography) » Wired EGG amplifier (BIOPAC EGG100D)
A wired electrogastrography (EGG) amplifier from the BIOPAC Smart Amplifier series — it records the slow-wave electrical activity of the stomach with a very narrow band (HP 0.005 Hz / LP 1 Hz). Measurement electronics at the electrode reduce interference and artifacts, and acquisition parameters configure automatically in AcqKnowledge. Requires the AMI100D interface and an MP160 or MP200 unit (not MP150), plus AcqKnowledge 5.0.4 or newer.
EGG100D is a Smart Amplifier series amplifier for recording the slow-wave electrical activity of the stomach (EGG) — the measurement electronics sit directly at the electrode, instead of in a module near the acquisition unit.
Thanks to the transducer's proximity, the signal is less susceptible to electromagnetic interference (EMI) and motion artifacts, and acquisition parameters configure automatically in AcqKnowledge once connected.
Illustrative photo of the entire Smart Amplifier 100D family — the EGG100D module has an identical housing.
The EGG100D module by itself does not record or store data on its own. It requires connection via the AMI100D interface to an MP160 or MP200 data acquisition unit (Smart Amplifier modules do NOT work with the MP150), together with AcqKnowledge version 5.0.4 or newer.
EGG100D uses the same general-purpose biopotential lead BN-EL*-LEAD2/LEAD3 as other biopotential modules in this series, together with electrodes — see the section below for details.
EGG100D is the amplifier itself — a separately ordered electrode lead and electrodes are needed for measurement. This module has no dedicated lead — it uses the same general-purpose biopotential lead as other 100D modules in this series.
Manufacturer photo (BIOPAC) — BN-EL-LEAD2 biopotential lead, shared across ECG/EMG/EOG/EGG/EEG.
BN-EL*-LEAD2 / LEAD3
A shared, universal electrode lead used across multiple biopotential modules in the 100D series (not a part dedicated solely to EGG100D). Indirect sources (manufacturer materials not directly confirmed, due to lack of access to biopac.com from this research environment) indicate that EGG100D is likely used with electrodes from the EL500 series on the abdominal skin surface — we treat this as medium-confidence information, to be verified when configuring the order.
The Smart Amplifier architecture places the amplifier right at the electrode — significantly reducing EMI interference and motion artifacts compared with a traditional module near the acquisition unit.
Once connected, the module automatically configures acquisition parameters in AcqKnowledge — no manual switch settings required.
HP 0.005 Hz / LP 1 Hz filters give the narrowest band in the entire 100D family — matched to the very slow nature of gastric electrical activity (so-called slow waves), which is orders of magnitude slower than typical biopotential signals (such as ECG or EMG).
Gold-plated electrodes should not be used — their high input impedance causes charge build-up and distorts the recorded signal.
Click the points on the silhouette to see the approximate placement of EGG electrodes on the abdominal skin surface, along the axis of the stomach.
Illustrative points, based on the commonly accepted convention for electrode placement in electrogastrography — this is NOT a confirmed, dedicated BIOPAC scheme for the EGG100D module. The exact number of electrodes and their spacing depend on the research protocol adopted.
Electrode on the abdominal skin, in the upper part of the gastric axis. Approximate position — general electrogastrography convention, not directly confirmed as a dedicated BIOPAC scheme for this module.
Electrode on the abdominal skin, in the middle part of the gastric axis. Approximate position — general electrogastrography convention, not directly confirmed as a dedicated BIOPAC scheme for this module.
Electrode on the abdominal skin, in the lower part of the gastric axis. Approximate position — general electrogastrography convention; the exact number of electrodes and their spacing depend on the research protocol adopted.
Electrodes connected via the BN-EL*-LEAD2/LEAD3 lead, placed along the axis of the stomach on the abdominal skin surface.
The module amplifies the slow-wave signal right at the electrode and sends it via an RJ12 cable to the AMI100D interface, and from there to the acquisition unit.
Automatic channel configuration and recording of the raw gastric slow-wave signal for further analysis.
Electrogastrography supports research into gastrointestinal motility and its links to the central nervous system.
Recording the slow-wave electrical activity of the stomach as an indicator of rhythm and gastrointestinal motility disorders.
Analysis of the links between gastric activity and processes in the central nervous system in brain–gut axis research.
Assessment of the effect of pharmacological substances on the rhythm and course of gastric peristalsis.
Supporting research into functional gastrointestinal disorders using EGG recording.
EGG100D places the amplifier directly at the electrode (instead of in a module near the acquisition unit), which reduces EMI interference and motion artifacts, and automatically configures parameters in AcqKnowledge. It also requires the AMI100D interface and an MP160/MP200 unit (not the MP150), unlike the older 100C series.
Ag/AgCl electrodes only, connected via the shared BN-EL*-LEAD2/LEAD3 biopotential lead. Indirect sources (manufacturer materials not directly confirmed, due to lack of access to biopac.com) likely point to electrodes from the EL500 series — this is medium-confidence information, requiring confirmation when configuring the order. Gold-plated electrodes are unsuitable regardless of the model — their high input impedance distorts the signal.
Only the MP160 or MP200, via the AMI100D interface, with AcqKnowledge software version 5.0.4 or newer. It does not work with the MP150.