Field test instruments and fusion splicers for network installers and operators.
102 products in this department
Browse the departmentLaboratory instrumentation for photonics, laser technology and R&D.
226 products in this department
Browse the departmentFiber-optic sensing systems: DAS, DTS, DSS, FBG and OFDR.
84 products in this department
Browse the departmentEye tracking, fNIRS, EEG and biometrics for science and business.
35 products in this department
Browse the departmentHome » Products » Photonics & R&D » OptoTest OP940-SW
The multichannel OP940 is an internally switched insertion loss (IL) and return loss (RL) meter designed for testing ribbon cables and multi-pin terminations.
A multichannel meter for insertion loss and return loss measurements. The meter is designed for measuring ribbon and multi-pin cables. It has a color LCD screen. It is capable of testing fiber optic cables quickly and precisely. It can include from 4 to 24 channels.
Simplified test setup
The OP940 measures quickly and accurately, without the need to wrap mandrels or apply index-matching gel.
The most accurate RL measurement
By using a wide dynamic range (-10dB to -80dB) for RL measurements, the multichannel OP940 is able to adjust the attenuation in the reference configuration, delivering the most accurate return loss results in the industry.
Easy maintenance and minimal downtime
To minimize downtime on large production lines due to optical end-face damage, the removable front panel provides access to the source connector, allowing the connector to be re-polished if it becomes damaged.
Customizability
The multichannel OP940 can be built with anywhere from 4 to 24 channels. The system is available with Single Mode, Multimode, and FTTX wavelengths, as well as various core sizes and detector options.
| 1mm InGaAs | 3mm InGaAS | 5mm InGaAs | 10mm InGaAs | 3mm Silicon | |
| Measurement range | +6dBm to -72dBm at 1490nm | +3dBm to -72dBm at 1490nm | 0dBm to -65dBm at 1490nm | 0dBm to -55dBm at 1490nm | 0dBm to -65dBm at 980nm |
| Wavelength range | 850nm to 1650nm | 400nm - 1100nm | |||
| Wavelength selectability | Standard wavelengths (850nm, 980nm, 1300nm, 1310nm, 1490nm, 1550nm, 1625nm) | Standard wavelengths (650nm, 850nm, 980nm) | |||
| Resolution (Display) | 0.001dB | ||||
| Accuracy | ±0.25 dB | ||||
| Measurements (relative accuracy) | |||||
| Deviation ± 0.05dB | +3dBm to -65m at 1490nm | 0dBm to -65dBm at 1490nm | 0dBm to -55dBm at 1490nm | 0dBm to -45dBm at 1490nm | 0dBm to -55dBm at 980nm |
| Deviation ± 0.01dB | <10dB variable power | <10dB variable power | <10dB variable power | <10dB variable power | <10dB variable power |